最新中文字幕av无码专区不卡_67194成是人免费无码_久久视频热_亚洲黄色小说视频_亚洲www视频_影视先锋AV资源噜噜

射頻探針
Model 10 (dc to 11 GHz )
 Model 10 (dc to 11 GHz )
  • 規格參數
  • 資料下載


PICOPROBE® MODEL 10

PICOPROBE® MODEL 10 is a multipurpose, high speed, passive probe which can be used for driving as well as receiving signals. The Model 10 consists of a one meter length of flexible 50 ohm coaxial cable terminated by a carefully trimmed SMA on one end and by a miniature, high speed 50 ohm connector, specially developed to receive Model 10 replaceable coaxial probe tips, on the other. The 50 ohm coaxial cable was custom designed for Model 10 to be high speed, yet very flexible, so that moving the cable would not disturb the probe points.

Adaptable for a wide range of applications, the Model 10 uses a variety of special purpose, easily replaceable probe tips. Each probe tip consists of a 1.5 inch long 50 ohm semi-rigid coaxial line, a retaining nut, one or two probe points, and a variety of electrical components tailored to achieve the desired electrical characteristics. To drive or receive signals on 50 ohm circuit points, the Model 10 should be fitted with a probe tip that has two probe points, one for the ground and one for the signal.

Probe points which extend 0.120 inches beyond the 50ohm coaxial probe tip have been designed fordc to 3.5 GHz response and probe points which extend 0.030 inches beyond the probe tip have been designed for dc to 7 GHz response. The longer 0.120 inch tips are more flexible, making them more durable and easier to use than the shorter 0.030 inch style.

To receive signals from high impedance circuit points, Model 10 probe tips with a 250 ohm, 500 ohm, or 5 k ohm input resistance should be used. All have been trimmed to compensate for cable loss and to minimize the need for a short ground. Grounding methods would depend upon the desired frequency response and range from dual probe points to a 6 inch long flexible ground strap. In applications where many circuit points must be accessed and ground is not conveniently located, a flexible ground strap can be substituted for the ground point.

The 250 ohm tip should be used with 0.180 inch long dual probe points to achieve dc to 10 GHz response. The signal will be attenuated by 5:1. The 500 ohm tip should be used either with 0.180 inch long dual probe points to achieve dc to 11 GHz response or with a 2 inch long ground strap to achieve dc to 4 GHz response. The signal will be attenuated by 10:1.

The 5k ohm tip should be used either with 0.180 inch long dual probe points to achieve dc to 5 GHz response, a 2 inch ground strap to achieve dc to 4 GHz response, or a 6 inch ground strap to achieve dc to 2 GHz response. The signal will be attenuated by 100:1.

To drive high impedance circuit points Model 10 probe tips with a 50 ohm terminating resistor should be used.

Model 10 was designed to be attached to any micropositioner for use on any probe station. Simply state the make and model number when ordering and the properly shaped probe will be delivered to you.



MODEL 10 SPECIFICATIONS
50 ohm input impedance mode
Probe Wire Length 0.120 inch 0.030 inch
Frequency Response: dc to 3.5 GHz dc to 7 GHZ
Insertion Loss: 3 dB 3 dB
Return Loss: greater than 10 dB greater than 10 dB
Attenuation: 1:1 1:1



250 ohm input impedance mode
Frequency Response dc to 10 GHz(-3 dB)
Attenuation> 5:1
500 ohm input impedance mode
Frequency Response: dc to 11 GHz(-3 dB)
Attenuation: 10:1


5K ohm input impedance mode
Frequency Response: dc to 5 GHz(-3 dB)
Attenuation: 100:1

Model 10 Replacement Tips
Part Number System
Model
Number
Added Resistance to
50 ohm Coaxial Tip
Outside Diameter of
Probing Wire
Probing Wire
Material
No. of
Probing Wires
Ground
R/L
Space Between
Points
10- 50/30 = no added resistance (50 ohm coax to 0.030" long probe tips) 125=125 micron wire sharpened to approx. 5 microns for tungsten and 25 microns for Pd or BeCu W=Tungsten 1=one signal wire only R=Right
L=Left
Ground on Right or Left side of signal point as seen looking from front to back of Model 10
Spacing between signal and ground points(indicate distance in inches or microns)
10- 50/120 = no added resistance (50 ohm coax to 0.120" long probe tips) 60=60 micron wire sharpened to approx. 3 microns for tungsten and 10 microns for Pd or BeCu Pd=Palladium
Only available in 200 micron diameter with 2.5 micron point radius or 12.5 micron point radius
2=one signal wire and one ground wire
10- 50T = 50 ohm resistor placed between center conductor and shield just before probe tips 35=35 micron wire sharpened to approx. 2 microns(tungsten only) BeCu=Beryllium Copper End Part Number here if "1" is entered
10- 50C =a capacitor placed between center conductor and shield just before probe tips(specify value) 22=22 micron wire sharpened to approx. 1 microns(tungsten only)
10- 250=250 ohm input resistor
attenuates 5:1
10=10 micron wire sharpened to approx. 0.2 microns(tungsten only)
10- 500=500 ohm input resistor
attenuates 10:1
10- 1K=1K ohm input resistor
attenuates 20:1
10- 2.5K=2.5K ohm input resistor
attenuates 50:1
10- 5K=5K ohm input resistor
attenuates 100:1

EXAMPLE:

10-500-60-W-2-R-120 micron – Denotes a Model 10 tip with 500 ohm input resistance, 60 micron probing wires, one signal and one ground wire made of tungsten, the ground is on the right side of the signal wire, and the space between probe points is 120 microns.









推薦產品
主站蜘蛛池模板: 91亚州熟女网站 | 亚洲av无码一区二区大桥未久 | 色哟哟精品丝袜一区二区 | 9色在线视频| free男子游泳部第三季 | 久操视频在线播放 | 中文天堂av在线 | 中文字幕一区免费 | 无码中文字幕人妻在线一区二区三区 | 欧美人与动牲交ZOZO | 1717精品视频在线观看 | 色偷偷偷亚洲综合网另类 | 性色AV无码久久一区二区三区 | 女人与牲口性恔配视频免费 | 精品一区二区三区中文字幕老牛 | 国产二级一片内射视频插放 | 日本伊人精品一区二区三区观看方式 | 日本无码人妻精品一区二区蜜桃 | 日日碰狠狠躁久久躁蜜桃 | 女十八毛片 | av在线播放色 | 人人澡人人澡 | 亚洲AV无码乱码在线观看看 | 国产特级精品毛片视频 | 国产免费一区二区三区视频天天爽 | 国产在线乱码一区二区三区 | 老头把我添高潮了A片故视频 | 国产成人精品免费 | 成人无码免费视频在线观看网址 | 亚洲综合另类欧在线美 | 国内一级片在线观看 | 99久久精品毛片免费播放高潮 | 99re6在线视频精品免费 | 日批在线观看视频 | 日韩免费在线视频观看 | 91精品午夜| 日本成本人片无码免费视频网站 | 一级中文片 | 欧美国产日韩亚洲中文 | 亚洲日韩一区二区一无码 | 欧美激情视频久久 |