最新中文字幕av无码专区不卡_67194成是人免费无码_久久视频热_亚洲黄色小说视频_亚洲www视频_影视先锋AV资源噜噜

射頻探針
67A (DC - 67 GHz)

Model 67A 射頻能力:DC-67GHZ;

分GSG、 GS 、SG 三種類型;
針尖不可替換;
引腳間距 25 to 1250 microns 可選。

  • 規(guī)格參數(shù)
  • 資料下載


High Performance Microwave Probes

Model 67A

Features
  • Coplanar probe tips
  • Any pitch from 25 to 1250 microns
  • Durable
  • DC to 67 GHz
  • Insertion loss less than 1.1db
  • Return loss greater than 14db
  • Measurement repeatability -80db
  • Individually spring loaded contacts
  • BeCu or Tungsten tips available
  • Variety of Footprints
  • Patented coaxial design
  • Available in thirteen styles
  • Custom configurations available


  • A coplanar probe with patented flexible tips, the MODEL 67A microwave probe sets new standards in microwave probing performance. Using low loss coaxial techniques, the Model 67A achieves an insertion loss of less than 1.1 db and a return loss of greater than 14 db through 67 GHz.

    With its individually spring loaded, Beryllium-Copper or optional Tungsten tips, the Picoprobe® Model 67A microwave probe provides reliable contacts, even when probing non-planar structures. This reliable low resistance contact is one of the keys to providing highly repeatable measurements. The Model 67A also provides direct viewing of the probe tips for accurate positioning.

    The Model 67A can be mounted in various adaptors for use with standard microwave probe stations. Custom mounts are available.

    Any pitch (tip spacing) from 25 to 1250 microns may be specified. The probe can be configured with Ground-Signal-Ground (G,S,G), Ground-Signal (G,S), or Signal-Ground (S,G) tip footprints. We recommend smaller pitches with a G,S,G footprint for best results.

    Connection to the Model 67A is through a female V connector.

    Flexible Tips for Flexible Probing

    Each Model 67A has patented, independently spring loaded tips which make contact to the probing surface. Because the tips are flexible they minimize circuit damage, increase probe life, and most importantly, provide a reliable individually spring loaded contact for each point. With a small amount of overdrive, the point scrubs the surface to make a reliable contact free of dust, dirt, and oxide contamination. The ability to view the exact contact area eases probe positioning and allows for the precise positioning necessary for good LRM calibrations. The flexible tips even allow probing of non-planar surfaces such as ceramic substrates and laser diode structures.

    Coaxial Transmission Improves Performance

    The Model 67A uses a precision miniature 50 ohm coaxial cable from the probe tips to the connector interface. The coaxial design provides lower loss and less radiation than traditional coplanar designs. The miniature coaxial cable is fabricated from flexible Beryllium-Copper which greatly improves the probe’s durability.

    Probe Cards

    Model 67A probes can be mounted on both standard 4.5 inch probe cards and custom-sized probe cards to provide a convenient method for testing wafers at high frequencies using standard automatic or manual probe stations. Picoprobe Probe Cards combine our Model 67A probe technology for RF connections with DC needles for power and low frequency signals.

    Multi-Contact Wedges

    Our unique Multi-Contact Wedge designs accommodate multiple RF and DC contacts on a single, compact adapter. This compact design provides the user with a convenient method for testing wafers at high frequencies using standard automatic or manual probe stations. The user can choose from a variety of wiring options for the DC or power needles and select any combination of 40, 50, 67, and/or 110 GHz RF probes.



    FIGURE 2

    Line of Microwave Probes

    An entire line of microwave probes are available with standard tip spacings of up to 2540 microns. Larger tip spacings are available as well. For special applications, the Model 67A can be mounted in custom adaptors, the coaxial line can be bent to fit tight spaces, and the tips can be configured to match extremely non-planar surfaces or non-symmetrically placed grounds.

    Other options include:
    Tungsten or Nickel probe tips;
    high temperature and high power versions;
    custom "chip" probes which have integrated series, parallel or termination components built into the signal tip.

    For applications below 40 GHz, GGB Industries, Inc., offers the Model 40A Picoprobe which uses the 2.9mm K connector. The Model 40A performs up to 40 GHz with less than 0.8 db insertion loss and return loss of greater than 18 db.

    For applications above 50 GHz, GGB Industries, Inc., offers a complete line of microwave probes operating up to 325 GHz (Model 325). Several models are available with wave guide inputs: WR-22 for 33 to 50 GHz, WR-15 for 50 to 75 GHz, WR-12 for 60 to 90 GHz, WR-10 for 75 to 120 GHz, WR-8 for 90 to 140 GHz, WR-5 for 140 to 220 GHz, and WR-3 for 325 GHz. The wave guide probes have an optional integral Bias T for active device measurements.  Many other types and custom designs are available, so please call with your special application requirements.

    Probing Expertise

    With more than 25 years of probing experience, GGB Industries has broad capabilities in custom probe engineering and manufacturing. Our staff is accustomed to creating unique solutions for the most difficult probing requirements demanded by our customers. GGB Industries, Inc., is the leading supplier of high impedance active probes offering models with input capacitances of as low as .02 pF and frequency responses of up to 26.0 GHz.

    ORDERING INFORMATION

    When ordering Model 67A probes, use the following part numbering convention:

    Model 67A - configuration - pitch - mounting style

    Configuration: Specify GSG, GS or SG for tip placement where S is the signal tip and G is a ground tip. Use the following diagram to determine the appropriate configuration.

    Pitch: Specify ground (G) to signal (S) tip spacing in Microns from 50 to 1250 microns. For standard GSG probes, the two spacings are equal. Contact the factory for spacings larger than 1250 microns or unusual tip placement and spacings.



    Mounting Style: Choose from thirteen adapter styles. Specify T, C, GR, P, DP, EDP, LP, Q, F, S, DS, VP, or RVP. Choose the appropriate mounting type for your application. The P, DP, EDP, LP, Q, S, DS, VP, and RVP styles have the connector pointing back at a 45 degree angle to give more working area above the probe. The DP, EDP, DS, VP, and RVP styles are used where extra clearance beneath the probe is needed. When using DP, EDP, and DS style probes, probe positioning is more difficult due to the increased probing angle since the probe points slide further forward for a given change in the Z axis than our other style probes. Custom mounting styles are available
    Example:A 67A-GSG-150-P is a Model 67A with Ground, Signal, Ground configuration with 150 microns between each contact mounted in a P style adaptor.






    推薦產(chǎn)品
    主站蜘蛛池模板: 亚洲欧美日韩精品在线 | 黄色网络视频 | 国产天美传媒性色AV | 一本一道AV无码中文字幕﹣百度 | 亚洲一二精品 | 欧美精品七区 | 久久日免费视频 | 三级全黄女人高潮 | 欧美日韩国产高清视频 | 国产精品久久av一区二区三区 | 毛片无限看 | 国产亚洲欧美一区二区三区四区 | 啊啊啊好爽啊 | 不卡一区二区三区四区五区 | 古代级a毛片可以免费看 | 肉大捧一进一出好爽mba | 亚洲国产第一站精品蜜芽 | 久久免费国产精品1 | 成人片又黄又爽免费视频 | 久草在线观看首页 | 久久久久99| 国产精品乱码高清在线看 | 少妇无码av无码专线区大牛影院 | 欧美性生活一区二区三区 | 少妇精品无码一区二区免费视频 | 亚洲精品一区二区三区蜜桃久 | 亚洲AV小说最新在线观看网址 | 麻豆精品视频在线 | 国产欧美日韩久久精品一区 | 国产欧美日韩另类在线专区 | 老师的双乳好大下面水好多视频 | 亚洲综合熟女久久久40P | 亚洲aⅴ在线视频 | 一区网站在线观看 | 天躁夜夜躁2021aa91 | 97SE亚洲国产综合自在线观看 | 嫩草影院啪啪 | 欧美人与动牲猛交a欧美精品 | 久久久久高潮 | 黑人巨大精品欧美一区二区小视频 | 中文无码一区二区视频在线播放 |